140 lines
3.1 KiB
HTML
140 lines
3.1 KiB
HTML
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML EXPERIMENTAL 970324//EN">
|
|
<HTML>
|
|
<HEAD>
|
|
<META NAME="GENERATOR" CONTENT="Adobe FrameMaker 5.5/HTML-Exportfilter">
|
|
<LINK REL="STYLESHEET" HREF="funktionen.css">
|
|
<TITLE> ACI [A]</TITLE></HEAD>
|
|
<BODY BGCOLOR="#ffffff">
|
|
<DIV>
|
|
<table BORDER=0 COLS=1 WIDTH="100%" BGCOLOR="#FFFFCC" NOSAVE ><tr ALIGN=CENTER VALIGN=CENTER NOSAVE><td NOSAVE><font face="Arial,Helvetica"><font size=+2></font></font><br><font face="Arial,Helvetica"><font size=+2>CCS Standardfunction <b>ACI [A]</b></font></font><br> </td></tr></table><p><p></DIV>
|
|
<H2 CLASS="Funktion">
|
|
<A NAME="pgfId=13323">
|
|
</A>
|
|
ACI [A]</H2>
|
|
<P CLASS="Meßparameter">
|
|
<A NAME="pgfId=13325">
|
|
</A>
|
|
MaxSignalAmplitude [V]</P>
|
|
<P CLASS="Meßparameter">
|
|
<A NAME="pgfId=13327">
|
|
</A>
|
|
Test_Duration [s]</P>
|
|
<P CLASS="Meßparameter">
|
|
<A NAME="pgfId=13329">
|
|
</A>
|
|
Test_Method [Str]</P>
|
|
<P CLASS="Normal">
|
|
<A NAME="pgfId=13331">
|
|
</A>
|
|
</P>
|
|
<DIV>
|
|
<H6 CLASS="FktBeschrTitel">
|
|
<A NAME="pgfId=13333">
|
|
</A>
|
|
Description of Function</H6>
|
|
<P CLASS="FktBeschrText">
|
|
<A NAME="pgfId=13335">
|
|
</A>
|
|
Measurement of current for periodically variable signals (sine-wave, square-wave, triangular, trapezoidal)</P>
|
|
<P CLASS="ParameterTitel">
|
|
<A NAME="pgfId=13337">
|
|
</A>
|
|
</P>
|
|
<P CLASS="ParameterTitel">
|
|
<A NAME="pgfId=13339">
|
|
</A>
|
|
Testing Points</P>
|
|
<P CLASS="ParameterBeschreibung">
|
|
<A NAME="pgfId=13341">
|
|
</A>
|
|
The control unit pin at which the current is to be measured is specified as the test point and the reference point.</P>
|
|
<P CLASS="Normal">
|
|
<A NAME="pgfId=13343">
|
|
</A>
|
|
</P>
|
|
<P CLASS="ParameterTitel">
|
|
<A NAME="pgfId=13345">
|
|
</A>
|
|
Parameters</P>
|
|
<P CLASS="ParameterTitel">
|
|
<A NAME="pgfId=13347">
|
|
</A>
|
|
</P>
|
|
<P CLASS="Meßparameter">
|
|
<A NAME="pgfId=13349">
|
|
</A>
|
|
MaxSignalAmplitude</P>
|
|
<P CLASS="ParameterBeschreibung">
|
|
<A NAME="pgfId=13351">
|
|
</A>
|
|
Largest amplitude occurring on the signal. Can be used to establish the measurement range or to select a suppressor circuit.</P>
|
|
<P CLASS="Parameter">
|
|
<A NAME="pgfId=13353">
|
|
</A>
|
|
</P>
|
|
<P CLASS="Meßparameter">
|
|
<A NAME="pgfId=13355">
|
|
</A>
|
|
Test_Duration</P>
|
|
<P CLASS="ParameterBeschreibung">
|
|
<A NAME="pgfId=13357">
|
|
</A>
|
|
Duration of the test necessary so that sufficient periods can be analyzed.</P>
|
|
<P CLASS="Parameter">
|
|
<A NAME="pgfId=13359">
|
|
</A>
|
|
</P>
|
|
<P CLASS="Meßparameter">
|
|
<A NAME="pgfId=13361">
|
|
</A>
|
|
Test_Method</P>
|
|
<P CLASS="ParameterBeschreibung">
|
|
<A NAME="pgfId=13363">
|
|
</A>
|
|
î = Peak value</P>
|
|
<P CLASS="ParameterBeschreibung">
|
|
<A NAME="pgfId=13365">
|
|
</A>
|
|
I< = Arithmetical mean</P>
|
|
<P CLASS="ParameterBeschreibung">
|
|
<A NAME="pgfId=13367">
|
|
</A>
|
|
Ieff = Effective value</P>
|
|
<P CLASS="Normal">
|
|
<A NAME="pgfId=13369">
|
|
</A>
|
|
</P>
|
|
<P CLASS="Beispiel">
|
|
<A NAME="pgfId=13371">
|
|
</A>
|
|
Example</P>
|
|
<P CLASS="Tabelle">
|
|
<A NAME="pgfId=13373">
|
|
</A>
|
|
</P>
|
|
<DIV>
|
|
<H6 CLASS="Body">
|
|
<A NAME="pgfId=13376">
|
|
</A>
|
|
</H6>
|
|
<TABLE BORDER="1">
|
|
<TR>
|
|
<TD ROWSPAN="1" COLSPAN="1">
|
|
<P CLASS="Tabelle">
|
|
<A NAME="pgfId=6565">
|
|
</A>
|
|
ACI</P>
|
|
</TD>
|
|
<TD ROWSPAN="1" COLSPAN="1">
|
|
<P CLASS="Tabelle">
|
|
<A NAME="pgfId=6567">
|
|
</A>
|
|
1, 0.1, Ieff</P>
|
|
</TD>
|
|
</TR>
|
|
</TABLE>
|
|
</DIV>
|
|
</DIV>
|
|
</BODY>
|
|
</HTML>
|