Files
CPXV2/CPXV2 PTS/References/GaudiCfg/help/macro/dci.html
2025-03-20 08:38:05 +09:00

205 lines
4.4 KiB
HTML

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML EXPERIMENTAL 970324//EN">
<HTML>
<HEAD>
<META NAME="GENERATOR" CONTENT="Adobe FrameMaker 5.5/HTML-Exportfilter">
<LINK REL="STYLESHEET" HREF="funktionen.css">
<TITLE> DCI [A] </TITLE></HEAD>
<BODY BGCOLOR="#ffffff">
<DIV>
<table BORDER=0 COLS=1 WIDTH="100%" BGCOLOR="#FFFFCC" NOSAVE ><tr ALIGN=CENTER VALIGN=CENTER NOSAVE><td NOSAVE><font face="Arial,Helvetica"><font size=+2></font></font><br><font face="Arial,Helvetica"><font size=+2>CCS Standardfunction &nbsp;&nbsp;<b>DCI [A] </b></font></font><br>&nbsp;</td></tr></table><p><p></DIV>
<H2 CLASS="Funktion">
<A NAME="pgfId=8673">
</A>
DCI [A] </H2>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=8675">
</A>
MaxSignalAmplitude [V]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=8677">
</A>
IntegrationPeriod [s]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=8679">
</A>
Shuntresistor [Ohm]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=8681">
</A>
</P>
<DIV>
<H6 CLASS="FktBeschrTitel">
<A NAME="pgfId=8683">
</A>
Description of Function</H6>
<P CLASS="FktBeschrText">
<A NAME="pgfId=8685">
</A>
Indirect measurement of current by means of integrating DC voltage measurement with AUTO triggering on a defined shunt. This function is always used when a load with integrated shunt is connected to a control unit pin and the current is to be measured on the integrated shunt. Currents flowing into the control unit register as positive.<BR>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=8687">
</A>
Testing Points</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=8689">
</A>
The control unit pin to which the load with the integrated shunt is connected is specified as the test point and the reference point.</P>
<P CLASS="FktBeschrText">
<A NAME="pgfId=8691">
</A>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=8693">
</A>
Parameters</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=8695">
</A>
MaxSignalAmplitude</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=8697">
</A>
Largest amplitude occurring on the signal. Can be used to establish the measurement range or to select a suppressor circuit.</P>
<P CLASS="Parameter">
<A NAME="pgfId=8699">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=8701">
</A>
IntegrationPeriod</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=8703">
</A>
Period over which the signal is integrated.<BR>
In the event of superimposed interference signals, it is advisable to select a multiple of the interference signal period as the integration period.<BR>
<BR>
Standard value: period duration of supply voltage.</P>
<P CLASS="Parameter">
<A NAME="pgfId=8705">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=8707">
</A>
Shuntresistor</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=8709">
</A>
For selection of resistor value see MSL Catalogue, Implementation of Modules (Simulated Loads).</P>
<P CLASS="Parameter">
<A NAME="pgfId=8711">
</A>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=8715">
</A>
Example<BR>
</P>
<DIV>
<H6 CLASS="Body">
<A NAME="pgfId=8718">
</A>
</H6>
<TABLE BORDER="1">
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=667">
</A>
DCI</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=669">
</A>
1,0.02,0.1</P>
</TD>
</TR>
</TABLE>
<P CLASS="Normal">
<A NAME="pgfId=8721">
</A>
<BR>
Test circuit:<BR>
<BR>
<IMG SRC="funktionen-4.gif" ALIGN="BASELINE">
<BR>
</P>
<P CLASS="Normal">
<A NAME="pgfId=8724">
</A>
<BR>
Diagram:<BR>
<BR>
<IMG SRC="funktionen-5.gif" ALIGN="BASELINE">
<BR>
</P>
</DIV>
<DIV>
<H6 CLASS="Body">
<A NAME="pgfId=8727">
</A>
</H6>
<TABLE BORDER="1">
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=676">
</A>
tID</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=678">
</A>
IntegrationPeriod</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=684">
</A>
tPS</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=686">
</A>
Period of the interference signal</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=692">
</A>
tN</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=694">
</A>
Period of mains power supply</P>
</TD>
</TR>
</TABLE>
<P CLASS="Normal">
<A NAME="pgfId=8729">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=8731">
</A>
Figure 2: Indirect current measurement on a shunt</P>
<P CLASS="Normal">
<A NAME="pgfId=8733">
</A>
</P>
</DIV>
</DIV>
</BODY>
</HTML>