<PRE>
$Id: p_skmtask.C,v 1.6 2005/09/01 07:11:40 sniff Exp $
---------------------------------------------------------------------
Kurzbeschreibung: Communicate with SKM
---------------------------------------------------------------------
Projekt: CCS
Sourcefile: p_skmtask.C
Autor: RtW2/TEF32-Wiese (30.10.03)
Zielsystem: HP9000/V743 (HP-RT 3.01) /Linux
Sprache: ANSI-C/C++
---------------------------------------------------------------------
Prototyp:
int p_skmtask
(shm_stringpointer *zeilen_wert // &lt;I&gt; Inputfield of INTERPRETERLIST
,long index1 // &lt;I&gt; INDEX in list
,long anzahl) // &lt;I&gt; Number of Elements for Loaddfile
---------------------------------------------------------------------
Aufruf:
error = p_skmtask
(zeilen_wert // &lt;I&gt; Inputfield of INTERPRETERLIST
,index1 // &lt;I&gt; INDEX in list
,anzahl) // &lt;I&gt; Number of Elements for Loaddfile
if (error != 0) // Errordescription ...
{
// Errorhandling ...
}
---------------------------------------------------------------------
Functiondescription:
This Modul sends parameter to the process or to the skm by itself.
Different Parameter can manage the function to the skm.
The number pf Parameters is variable and is different from function to function.
Input parameter description:</pre><b><a name="param1">1</a> PRUEFSCHRITT:</b><pre> Step in plist</pre><b><a name="param2">2</a> POSITION:</b><pre> Position of step</pre><b><a name="param3">3</a> FUNKTION:</b><pre> Only CANSTART realized</pre><b><a name="param4">4</a> SUBFUNKTION:</b><pre> Only GM1 realized</pre><b><a name="param5">5</a> MODE</b><pre> S:Send G:get L: SendGet</pre><b><a name="param6">6</a> SUBMODE</b><pre> Not used</pre><b><a name="param7">7</a> PARA1</b><pre> Function Specific see below
.....</pre><b><a name="param26">26</a> PARA20</b><pre>
The Modul sends many parameter to the process skm o.a and works like
described under funktion and subfunktion
Not all parameters are used in all funktions
The Parameters are send to SKM with BLOCKTITLE SA.
FUNKTION CANSTART // SUBFUNKTION GM1:
Funktion like Dokument RB Entry Condition on CAN by AE/EWG Brand from 28.1.03
- Send "FIRSTSENDMESSAGE" until TOSEND1.
- read message from ECU with TOREC1 and compare it with FIRSTREADMESSAGE
- wait WSEND2
- send SECONDSENDMESSAGE with TOSEND2
- read message from ECU with TOREC2 and compare it with SECONDREADMESSAGE
FUNKTION=CANSTART
SUBFUNKTION: GM1
MODE:SEND
SUBMODE=""
PARA1=SENDIDENTIFIER :777
PARA2=SENDIDENTIFIERLEN :11
PARA3=READIDENTIFIER :778
PARA4=READIDENTIFIERLEN :11
PARA5=FIRSTSENDMESSAGE :075242454E545259
PARA6=FIRSTREADMESSAGE :075242454E545259
PARA7=SECONDSENDMESSAGE :04495800FF000000
PARA8=SECONDREADMESSAGE :04495800FF000000
PARA9=TOSEND1 (ms) :2000
PARA10=TOREC1 (ms) :10
PARA11=WSEND2 (ms) :100
PARA12=TOSEND2 (ms) :10
PARA13=TOREC2 (ms) :100
The communication starts to SKM with SA and switches to function with "CSGM"
Rof this the data starts with "U""4"&lt;CSGM&gt;
The data will be send in format (&lt;FORMATBYTE&gt;&lt;LENBYTE&gt;&lt;LENBYTEDATA&gt;)*n
FORMATBYTE: U -&gt; The data ist a unsigned long int
S -&gt; The data ist a unsigned short int
H -&gt; The data ist a hexstring and will be send in binary
A -&gt; The data is a charstring and send as is
</PRE>