Files
2024-06-26 10:30:00 +09:00

200 lines
6.6 KiB
C#

using System;
using System.Threading.Tasks;
using System.Net.NetworkInformation;
using System.Threading;
using SystemX.Net.Platform.Common.Event;
using SystemX.Net.Platform.Common.Util;
using static SystemX.PLC.Interface.PLCCommDefinition;
namespace SystemX.PLC.Interface.McProtocol
{
public class PLCModMxCMgr
{
public event EventPLCHandler EventPLC;
public FunctionEventHandler EventAlwaysUpdate { get; set; }
public FunctionEventHandler EventChangeUpdate { get; set; }
public PLCDeviceMXC plcDev;
PLCConnectionInfo PLCInfo;
public string CPU_TYPE_STR { set; get; } //Example: "Q03UDECPU";
public string PLC_IP_ADDR { set; get; }
public int PLC_PORT_NUMBER { set; get; }
public string CONNECTION_TYPE_STR { set; get; }
public int TIMEOUT { set; get; }
public bool IsOpened { get; set; } = false;
public PLCModMxCMgr(PLCConnectionInfo infoinput)
{
PLCInfo = infoinput;
}
public bool CloseDevice()
{
bool bResult = plcDev.DevClose();
IsOpened = !bResult;
return true;
}
public bool OpenDevice()
{
if (IsOpened == true)
return IsOpened;
plcDev = new PLCDeviceMXC();
EventChangeUpdate = new FunctionEventHandler();
plcDev.FuncEvtHndl = EventChangeUpdate;
plcDev.DeviceID = PLCInfo.Name;
plcDev.CPU_TYPE_STR = PLCInfo.CPUType;
plcDev.PLC_IP_ADDR = PLCInfo.IP;
plcDev.PLC_PORT_NUMBER = Convert.ToInt32(PLCInfo.Port);
plcDev.CONNECTION_TYPE_STR = PLCInfo.ConnectionType != "UDP" ? "TCP" : "UDP";
plcDev.READPORT = (PLCInfo.RWType == PLCCommDefinition.ePLCRWType.Read.ToString()) ? true : false;
plcDev.TIMEOUT = Convert.ToInt32(PLCInfo.Timeout);
EventChangeUpdate.OnReceive += FuncEvtHndl_OnPLCReceive;
Task<bool> conPing = new Task<bool>(() => PingToPLC());
conPing.Start();
Task<bool> conPLC = conPing.ContinueWith(x => ConnectToPLC());
return true;
}
public bool PingToPLC()
{
try
{
Ping pingtoPLC = new Ping();
int nCount = 0;
while (true)
{
PingReply reply = pingtoPLC.Send(plcDev.PLC_IP_ADDR);
if (reply.Status == IPStatus.Success)
break;
LogMessage.MessageOutput.ConsoleWrite($"PLC Connection Failed. Retry #{nCount} - IP:{plcDev.PLC_IP_ADDR}, Port:{plcDev.PLC_PORT_NUMBER}", ConsoleColor.Red, LogMessage.LogMessageLevel.FATAL);
Thread.Sleep(1000);
nCount++;
}
return true;
}
catch (Exception ex)
{
LogMessage.MessageOutput.ConsoleWrite($" - PLC Connection error: {PLCInfo.Name}, {PLCInfo.IP}:{PLCInfo.Port} - {PLCInfo.ConnectionType}", ConsoleColor.Blue, LogMessage.LogMessageLevel.NONE);
LogMessage.MessageOutput.ConsoleWrite($" -> Reason: {ex.Message}", ConsoleColor.Blue, LogMessage.LogMessageLevel.NONE);
throw;
}
}
public bool ConnectToPLC()
{
try
{
IsOpened = plcDev.DevOpen();
if (IsOpened == false)
plcDev = null;
LogMessage.MessageOutput.ConsoleWrite($"PLC Connection Success. - IP:{plcDev.PLC_IP_ADDR}, Port:{plcDev.PLC_PORT_NUMBER} ", ConsoleColor.Green, LogMessage.LogMessageLevel.NONE);
return IsOpened;
}
catch (Exception ex)
{
LogMessage.MessageOutput.ConsoleWrite($" - PLC Connection error: {PLCInfo.Name}, {PLCInfo.IP}:{PLCInfo.Port} - {PLCInfo.ConnectionType}", ConsoleColor.Blue, LogMessage.LogMessageLevel.NONE);
LogMessage.MessageOutput.ConsoleWrite($" -> Reason: {ex.Message}", ConsoleColor.Blue, LogMessage.LogMessageLevel.NONE);
throw;
}
}
private void FuncEvtHndl_OnPLCReceive(object sender, object objdata)
{
string data = objdata as string;
if (data == null)
return;
if (data.Contains(";"))
{
string address = data.Split(';')[0];
int value = Convert.ToInt32(data.Split(';')[1]);
EventPLC?.Invoke(address, value);
}
}
public async Task SingleScanStartAsync()
{
if (!IsOpened) return;
await plcDev.SingleScanStartAsync();
}
public bool AddDevices(string deviceNames)
{
if (!IsOpened) return false;
return plcDev.AddDevices(deviceNames);
}
public int ReadDevice(string deviceName)
{
try
{
if (!IsOpened) return -1;
return plcDev.ReadDevice(deviceName);
}
catch (Exception ex)
{
LogMessage.MessageOutput.ConsoleWrite($"PLC Device Reading Error in PLCModMxCMgr: {deviceName}", ConsoleColor.Red, LogMessage.LogMessageLevel.NONE);
LogMessage.MessageOutput.ConsoleWrite($" - Detail: {ex.Message}", ConsoleColor.Red, LogMessage.LogMessageLevel.NONE);
throw;
}
}
public int[] ReadBlockDevice(string deviceName, int nLength)
{
try
{
if (!IsOpened) return null;
return plcDev.ReadBlockDevice(deviceName, nLength);
}
catch (Exception ex)
{
LogMessage.MessageOutput.ConsoleWrite($"PLC Device Reading Error in PLCModMxCMgr: {deviceName}", ConsoleColor.Red, LogMessage.LogMessageLevel.NONE);
LogMessage.MessageOutput.ConsoleWrite($" - Detail: {ex.Message}", ConsoleColor.Red, LogMessage.LogMessageLevel.NONE);
throw;
}
}
public bool WriteDevice(string deviceName, int value)
{
if (!IsOpened) return false;
return plcDev.WriteDevice(deviceName, value);
}
public bool WriteBlockDevice(string deviceName, int nLength, int[] aValues)
{
if (!IsOpened) return false;
return plcDev.WriteBlockDevice(deviceName, nLength, aValues);
}
public bool WriteBitDevice(string deviceName, int[] value)
{
if (!IsOpened) return false;
return plcDev.WriteBitDevice(deviceName, value);
}
}
}