Files
2025-03-20 08:38:05 +09:00

1119 lines
23 KiB
HTML

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML EXPERIMENTAL 970324//EN">
<HTML>
<HEAD>
<META NAME="GENERATOR" CONTENT="Adobe FrameMaker 5.5/HTML-Exportfilter">
<LINK REL="STYLESHEET" HREF="funktionen.css">
<TITLE> K2000Ini []</TITLE></HEAD>
<BODY BGCOLOR="#ffffff">
<DIV>
<table BORDER=0 COLS=1 WIDTH="100%" BGCOLOR="#FFFFCC" NOSAVE ><tr ALIGN=CENTER VALIGN=CENTER NOSAVE><td NOSAVE><font face="Arial,Helvetica"><font size=+2></font></font><br><font face="Arial,Helvetica"><font size=+2>CCS Standardfunction &nbsp;&nbsp;<b>K2000Ini []</b></font></font><br>&nbsp;</td></tr></table><p><p></DIV>
<H2 CLASS="Funktion">
<A NAME="pgfId=10864">
</A>
K2000Ini []</H2>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10866">
</A>
Target_Address [INT]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10868">
</A>
Initialization_Type [INT]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10870">
</A>
Initialization_Line [INT]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10872">
</A>
P1max [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10874">
</A>
P2max [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10876">
</A>
P3min [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10878">
</A>
P3max [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10880">
</A>
P4min [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10882">
</A>
W1 [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10884">
</A>
W2 [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10886">
</A>
W3 [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10888">
</A>
W4min [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10890">
</A>
W4max [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10892">
</A>
W5 [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10894">
</A>
TiniL [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10896">
</A>
TWuP [ms]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10898">
</A>
BaudRate [INT]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10900">
</A>
KeepTesterPresent [INT]</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10902">
</A>
Target_Address 5Baud_Stimulation [INT]</P>
<P CLASS="Normal">
<A NAME="pgfId=10904">
</A>
</P>
<DIV>
<H6 CLASS="FktBeschrTitel">
<A NAME="pgfId=10906">
</A>
Description of Function</H6>
<P CLASS="FktBeschrText">
<A NAME="pgfId=10908">
</A>
Initializes and establishes communication via the diagnosis interface for the KW2000 protocol. In contrast with the function <EM CLASS="HelpSprung">
ComInit</EM>
<EM CLASS="HelpSprungverweis">
IDH_ComInit</EM>
, which applies to all protocols (but does not permit any protocol-specific parameter settings), the function K2000Ini specifies all parameters that are required to establish serial communication. For KWP2000 communication via the CAN, the function CAN2000Ini can be used.<BR>
<BR>
This function only supports physical addressing.<BR>
<BR>
This function does not return a value.<BR>
<BR>
Caution! The timing parameters to be specified in the testing function apply to the tester and are generally different from the settings programmed on the control unit.</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=10910">
</A>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=10912">
</A>
Testing Points</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10914">
</A>
None</P>
<P CLASS="FktBeschrText">
<A NAME="pgfId=10916">
</A>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=10918">
</A>
Parameters</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10920">
</A>
Target_Address</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10922">
</A>
Specifies the KW2000 address of the control unit. Permissible values are 0 ... 255.</P>
<P CLASS="Parameter">
<A NAME="pgfId=10924">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10926">
</A>
Initialization_Type</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10928">
</A>
Specifies the type of initialization (stimulation)</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10930">
</A>
0 &AElig; No initialization <BR>
(This mode is used to set/alter communication parameters for the tester without re-establishing communication or interrupting communication in progress.)</P>
<P CLASS="Parameter">
<A NAME="pgfId=10932">
</A>
1&AElig; 5-Baud initialization</P>
<P CLASS="Parameter">
<A NAME="pgfId=10934">
</A>
2&AElig; Quick initialization</P>
<P CLASS="Parameter">
<A NAME="pgfId=10936">
</A>
3&AElig; Terminate communication</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10938">
</A>
Default setting: 2</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10940">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10942">
</A>
Initialization_Line</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10944">
</A>
Specifies the lines on which initialization (stimulation) is to take place.<BR>
0 &AElig; K + L lead<BR>
1 &AElig; L lead<BR>
2 &AElig; K lead<BR>
<BR>
Default setting: 0</P>
<P CLASS="Beispiel">
<A NAME="pgfId=10946">
</A>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=10948">
</A>
Timing parameters for communication between tester and control unit (parameters P1 .. P4 as per Keyword Protocol 2000; for explanations, refer to <EM CLASS="HelpSprung">
Diagram</EM>
<EM CLASS="HelpSprungverweis">
TimingParameter1</EM>
with the same title. The suffix min or max is appended to the parameter name in order to indicate that either the minimum or maximum figure is to be specified).</P>
<P CLASS="Tabelle">
<A NAME="pgfId=10950">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10952">
</A>
P1max</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10954">
</A>
Specifies the maximum time the tester must wait between the receipt of 2 bytes.<BR>
<BR>
Default value: 20 <BR>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10956">
</A>
P2max</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10958">
</A>
Specifies the maximum time the tester must wait for a response from the control unit.<BR>
<BR>
Default value for normal timing: 50 ms<BR>
Default value for extended timing: 1000 ms<BR>
Resolution: 25 ms (to 6 s; beyond that, the resolution becomes coarser; refer to Keyword Protocol 2000 documentation).</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10960">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10962">
</A>
P3min</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10964">
</A>
Specifies the time the tester has to wait after a response from the control unit before it can start a new query.<BR>
<BR>
Default value for normal timing: 55 ms<BR>
Default value for extended timing: 0 ms<BR>
Resolution: 0.5 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10966">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10968">
</A>
P3max</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10970">
</A>
Specifies the maximum period that is allowed to elapse after a response from the control unit before the tester has to start a new query (to prevent communication breaking down). (Special case: P3Max = 0 ms is interpreted as no time limit, i.e. P3Max = &#183;.)<BR>
<BR>
Default value: 5000 ms<BR>
Resolution: 250 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10972">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10974">
</A>
P4min</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10976">
</A>
Specifies the minimum time the tester must wait between sending 2 bytes.<BR>
<BR>
Default value: 5 ms<BR>
Resolution: 0.5 ms</P>
<P CLASS="Beispiel">
<A NAME="pgfId=10978">
</A>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=10980">
</A>
Timing parameters for 5-baud initialization (parameters W1 .. P4 as per Keyword Protocol 2000; for explanations, refer to <EM CLASS="HelpSprung">
Diagram</EM>
<EM CLASS="HelpSprungverweis">
TimingParameter2</EM>
with the same title. The suffix min or max is appended to the parameter in order to indicate that either the minimum or maximum figure is to be specified).</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10982">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10984">
</A>
W1max</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10986">
</A>
Specifies the maximum period the tester must wait during 5-baud initialization for the synchronization word from the control unit after sending the address.<BR>
<BR>
Default value: 300 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10988">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10990">
</A>
W2max</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10992">
</A>
Specifies the maximum period the tester must wait for KB1 during 5-baud initialization after receipt of the synchronization word.<BR>
<BR>
Default value: 20 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10994">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=10996">
</A>
W3max</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=10998">
</A>
Specifies the maximum period the tester must wait for KB2 during 5-baud initialization after receipt of KB1.<BR>
<BR>
Default value: 20 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11000">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11002">
</A>
W4min</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11004">
</A>
Specifies the maximum period the tester must wait during 5-baud initialization after receiving KB2 before it can send the inverted KB2 back to the control unit.<BR>
<BR>
Default value: 25 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11006">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11008">
</A>
W4max</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11010">
</A>
Specifies the maximum period the tester must wait during 5-baud initialization for the response from the control unit (inverted control unit address) after sending the inverted KB2.<BR>
<BR>
Default value: 50 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11012">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11014">
</A>
W5min</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11016">
</A>
Specifies the minimum period the tester must wait (after control unit is switched on) before it can start establishing communication (sending the address byte). This figure applies both to 5-baud initialization and to quick initialization.<BR>
<BR>
Default value: 300 ms<BR>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=11018">
</A>
Timing parameters for quick initialization (Parameters TiniL and TWuP as per Keyword Protocol 2000; for explanation see <EM CLASS="HelpSprung">
diagram</EM>
<EM CLASS="HelpSprungverweis">
TimingParameter3</EM>
of the same name.</P>
<P CLASS="Parameter">
<A NAME="pgfId=11020">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11022">
</A>
TiniL</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11024">
</A>
Specifies Low period for the wake-up pattern.<BR>
<BR>
Default value: 25 ms</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11026">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11028">
</A>
TWuP</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11030">
</A>
Specifies total duration of wake-up pattern (Low phase + High phase).<BR>
<BR>
Default value: 50 ms<BR>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=11032">
</A>
</P>
<P CLASS="ParameterTitel">
<A NAME="pgfId=11034">
</A>
Other parameters:</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11036">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11038">
</A>
BaudRate</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11040">
</A>
Specifies the baud rate for communication.<BR>
<BR>
Default value: 10400</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11042">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11044">
</A>
KeepTesterPresent</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11046">
</A>
Specifies whether the tester should send Tester Present messages to the control unit of its own accord to prevent communication breaking down.<BR>
<BR>
The following values are allowed:<BR>
</P>
<DIV>
<H6 CLASS="Body">
<A NAME="pgfId=11049">
</A>
</H6>
<TABLE BORDER="1">
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=2036">
</A>
0</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=2038">
</A>
Do not send Tester Present messages</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=2044">
</A>
1</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=2046">
</A>
Automatically send Tester Present message if the period specified by P3max has elapsed since the last communication.</P>
</TD>
</TR>
</TABLE>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11051">
</A>
</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11053">
</A>
Default setting: 0</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11055">
</A>
</P>
<P CLASS="Me&szlig;parameter">
<A NAME="pgfId=11057">
</A>
Target_Address 5Baud_Stimulation [Dec]</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11059">
</A>
Target address for 5-baud stimulation.</P>
<P CLASS="Normal">
<A NAME="pgfId=11061">
</A>
</P>
<P CLASS="Beschreibung">
<A NAME="pgfId=11063">
</A>
<EM CLASS="HelpFu&szlig;note">
</EM>
Timing parameters for communication between tester and control unit (excerpt from Keyword Protocol 2000 Part 2)</P>
<P CLASS="Parameter">
<A NAME="pgfId=11065">
</A>
</P>
<P CLASS="ParameterBeschreibung">
<A NAME="pgfId=11068">
</A>
<IMG SRC="funktionen-18.gif" ALIGN="BASELINE">
</P>
<P CLASS="Normal">
<A NAME="pgfId=11070">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11072">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11074">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11076">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11078">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11080">
</A>
</P>
</DIV>
<DIV>
<H6 CLASS="Body">
<A NAME="pgfId=11083">
</A>
</H6>
<TABLE BORDER="1">
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2053">
</A>
<EM CLASS="KWP2000TNR10">
Value</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2055">
</A>
<EM CLASS="KWP2000TNR10">
Description</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2061">
</A>
<EM CLASS="KWP2000TNR10">
P1</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2063">
</A>
<EM CLASS="KWP2000TNR10">
Inter byte time for server (ECU) response</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2069">
</A>
<EM CLASS="KWP2000TNR10">
P2</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2071">
</A>
<EM CLASS="KWP2000TNR10">
Time between client (tester) request and server (ECU) response or two server (ECU) responses</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2077">
</A>
<EM CLASS="KWP2000TNR10">
P3</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2079">
</A>
<EM CLASS="KWP2000TNR10">
Time between end of server (ECU) responses and start of new client (tester) request</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2085">
</A>
<EM CLASS="KWP2000TNR10">
P4</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="TableKWP2000TNR9">
<A NAME="pgfId=2087">
</A>
<EM CLASS="KWP2000TNR10">
Inter byte time for client (tester) request</EM>
</P>
</TD>
</TR>
</TABLE>
<P CLASS="Beschreibung">
<A NAME="pgfId=11085">
</A>
</P>
<P CLASS="Beschreibung">
<A NAME="pgfId=11087">
</A>
Timing parameters for 5-baud initialization (excerpt from Keyword Protocol 2000 Part 2)</P>
<P CLASS="Normal">
<A NAME="pgfId=11089">
</A>
</P>
<P CLASS="Beschreibung">
<A NAME="pgfId=11092">
</A>
<IMG SRC="funktionen-19.gif" ALIGN="BASELINE">
</P>
</DIV>
<DIV>
<H6 CLASS="Body">
<A NAME="pgfId=11095">
</A>
</H6>
<TABLE BORDER="1">
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2098">
</A>
<EM CLASS="KWP2000TNR10">
Timing</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="2">
<P CLASS="Normal">
<A NAME="pgfId=2100">
</A>
<EM CLASS="KWP2000TNR10">
Values in ms</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="ZelleHaupttext">
<A NAME="pgfId=2096">
</A>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2110">
</A>
<EM CLASS="KWP2000TNR10">
Parameters</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2112">
</A>
<EM CLASS="KWP2000TNR10">
min.</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2114">
</A>
<EM CLASS="KWP2000TNR10">
max.</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2116">
</A>
<EM CLASS="KWP2000TNR10">
Description</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2126">
</A>
<EM CLASS="KWP2000TNR10">
W1</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2128">
</A>
<EM CLASS="KWP2000TNR10">
60</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2130">
</A>
<EM CLASS="KWP2000TNR10">
300</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2132">
</A>
<EM CLASS="KWP2000TNR10">
Time from end of the address byte to start of synchronisation pattern</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2142">
</A>
<EM CLASS="KWP2000TNR10">
W2</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2144">
</A>
<EM CLASS="KWP2000TNR10">
5</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2146">
</A>
<EM CLASS="KWP2000TNR10">
20</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2148">
</A>
<EM CLASS="KWP2000TNR10">
Time from end of the synchronisation pattern to the start of key byte 1</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2158">
</A>
<EM CLASS="KWP2000TNR10">
W3</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2160">
</A>
<EM CLASS="KWP2000TNR10">
0</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2162">
</A>
<EM CLASS="KWP2000TNR10">
20</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2164">
</A>
<EM CLASS="KWP2000TNR10">
Time between key byte 1 and key byte 2</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2174">
</A>
<EM CLASS="KWP2000TNR10">
W4</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2176">
</A>
<EM CLASS="KWP2000TNR10">
25</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2178">
</A>
<EM CLASS="KWP2000TNR10">
50</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2180">
</A>
<EM CLASS="KWP2000TNR10">
Time between key byte 2 (from the server (ECU)) and its inversion from the client (tester). Also the time from the inverted key byte 2 from the client (tester) and the inverted address from the server (ECU)</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2190">
</A>
<EM CLASS="KWP2000TNR10">
W5</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2192">
</A>
<EM CLASS="KWP2000TNR10">
300</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2194">
</A>
<EM CLASS="KWP2000TNR10">
-</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2196">
</A>
<EM CLASS="KWP2000TNR10">
Time before the client (tester) starts to transmit the address byte</EM>
</P>
</TD>
</TR>
</TABLE>
</DIV>
</DIV>
<DIV>
<H6 CLASS="Standardtext">
<A NAME="pgfId=11097">
</A>
</H6>
<P CLASS="Beschreibung">
<A NAME="pgfId=11099">
</A>
Timing parameters for quick initialization (excerpt from Keyword Protocol 2000 Part 2)</P>
<P CLASS="Normal">
<A NAME="pgfId=11102">
</A>
<IMG SRC="funktionen-20.gif">
</P>
<P CLASS="Normal">
<A NAME="pgfId=11104">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11106">
</A>
</P>
<DIV>
<H6 CLASS="Body">
<A NAME="pgfId=11109">
</A>
</H6>
<TABLE BORDER="1">
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2207">
</A>
<EM CLASS="KWP2000TNR10">
timing parameter</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2209">
</A>
<EM CLASS="KWP2000TNR10">
minimum timing value</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2211">
</A>
<EM CLASS="KWP2000TNR10">
timing value</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2213">
</A>
<EM CLASS="KWP2000TNR10">
maximum timing value</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2223">
</A>
<EM CLASS="KWP2000TNR10">
TiniL</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2225">
</A>
<EM CLASS="KWP2000TNR10">
24 ms</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2227">
</A>
<EM CLASS="KWP2000TNR10">
25 +/- 1 ms</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2229">
</A>
<EM CLASS="KWP2000TNR10">
26 ms</EM>
</P>
</TD>
</TR>
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2239">
</A>
<EM CLASS="KWP2000TNR10">
TWuP</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2241">
</A>
<EM CLASS="KWP2000TNR10">
49 ms</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2243">
</A>
<EM CLASS="KWP2000TNR10">
50 +/- 1 ms</EM>
</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Normal">
<A NAME="pgfId=2245">
</A>
<EM CLASS="KWP2000TNR10">
51 ms</EM>
</P>
</TD>
</TR>
</TABLE>
<P CLASS="Beispiel">
<A NAME="pgfId=11111">
</A>
<EM CLASS="KWP2000TNR10">
</EM>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=278968">
</A>
<EM CLASS="KWP2000TNR10">
</EM>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=278969">
</A>
<EM CLASS="KWP2000TNR10">
</EM>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=278970">
</A>
<EM CLASS="KWP2000TNR10">
</EM>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=278971">
</A>
<EM CLASS="KWP2000TNR10">
</EM>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=278972">
</A>
<EM CLASS="KWP2000TNR10">
Tidle = W5</EM>
</P>
<P CLASS="Tabelle">
<A NAME="pgfId=11113">
</A>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=11115">
</A>
</P>
<P CLASS="Beispiel">
<A NAME="pgfId=11117">
</A>
Example (Target address: 1; otherwise default settings for extended timing, target address for 5-baud stimulation: 1)</P>
<P CLASS="Tabelle">
<A NAME="pgfId=11119">
</A>
</P>
</DIV>
<DIV>
<H6 CLASS="Body">
<A NAME="pgfId=11122">
</A>
</H6>
<TABLE BORDER="1">
<TR>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=2252">
</A>
K2000Ini</P>
</TD>
<TD ROWSPAN="1" COLSPAN="1">
<P CLASS="Tabelle">
<A NAME="pgfId=2254">
</A>
1, 2, 0, 20, 1000, 0, 5000, 5, 300, 20, 20, 25, 50, 300, 25, 50 ,10400,0,1</P>
</TD>
</TR>
</TABLE>
<P CLASS="Normal">
<A NAME="pgfId=11124">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11126">
</A>
</P>
<P CLASS="Normal">
<A NAME="pgfId=11128">
</A>
</P>
</DIV>
</DIV>
</BODY>
</HTML>