CCS Standardfunction DCIS [A] |
Indirect measurement of current by means of integrating DC voltage measurement with AUTO triggering on a defined measurement resistor. This function is always used when a current measurement resistor has to be inserted in a line to the control unit (e.g. UB) for the duration of the measurement. Currents flowing into the control unit register as positive.
The control unit pin at which the current is to be measured is specified as the test point and the reference point.
Largest amplitude occurring on the signal. Can be used to establish the measurement range or to select a suppressor circuit.
Period over which the signal is integrated.
In the event of superimposed interference signals, it is advisable to select a multiple of the interference signal period as the integration period.
Standard value: period duration of supply voltage.
For selection of resistor level see MSL Catalogue, Current Measurement Using Series Resistor
The maximum permissible testing impedance is specified as the parameter.