CCS Standardfunction DCI [A] |
Indirect measurement of current by means of integrating DC voltage measurement with AUTO triggering on a defined shunt. This function is always used when a load with integrated shunt is connected to a control unit pin and the current is to be measured on the integrated shunt. Currents flowing into the control unit register as positive.
The control unit pin to which the load with the integrated shunt is connected is specified as the test point and the reference point.
Largest amplitude occurring on the signal. Can be used to establish the measurement range or to select a suppressor circuit.
Period over which the signal is integrated.
In the event of superimposed interference signals, it is advisable to select a multiple of the interference signal period as the integration period.
Standard value: period duration of supply voltage.
For selection of resistor value see MSL Catalogue, Implementation of Modules (Simulated Loads).