<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML EXPERIMENTAL 970324//EN">
|
||||
<HTML>
|
||||
<HEAD>
|
||||
<META NAME="GENERATOR" CONTENT="Adobe FrameMaker 5.5/HTML-Exportfilter">
|
||||
<LINK REL="STYLESHEET" HREF="funktionen.css">
|
||||
<TITLE> DCI [A] </TITLE></HEAD>
|
||||
<BODY BGCOLOR="#ffffff">
|
||||
<DIV>
|
||||
<table BORDER=0 COLS=1 WIDTH="100%" BGCOLOR="#FFFFCC" NOSAVE ><tr ALIGN=CENTER VALIGN=CENTER NOSAVE><td NOSAVE><font face="Arial,Helvetica"><font size=+2></font></font><br><font face="Arial,Helvetica"><font size=+2>CCS Standardfunction <b>DCI [A] </b></font></font><br> </td></tr></table><p><p></DIV>
|
||||
<H2 CLASS="Funktion">
|
||||
<A NAME="pgfId=8673">
|
||||
</A>
|
||||
DCI [A] </H2>
|
||||
<P CLASS="Meßparameter">
|
||||
<A NAME="pgfId=8675">
|
||||
</A>
|
||||
MaxSignalAmplitude [V]</P>
|
||||
<P CLASS="Meßparameter">
|
||||
<A NAME="pgfId=8677">
|
||||
</A>
|
||||
IntegrationPeriod [s]</P>
|
||||
<P CLASS="Meßparameter">
|
||||
<A NAME="pgfId=8679">
|
||||
</A>
|
||||
Shuntresistor [Ohm]</P>
|
||||
<P CLASS="Meßparameter">
|
||||
<A NAME="pgfId=8681">
|
||||
</A>
|
||||
</P>
|
||||
<DIV>
|
||||
<H6 CLASS="FktBeschrTitel">
|
||||
<A NAME="pgfId=8683">
|
||||
</A>
|
||||
Description of Function</H6>
|
||||
<P CLASS="FktBeschrText">
|
||||
<A NAME="pgfId=8685">
|
||||
</A>
|
||||
Indirect measurement of current by means of integrating DC voltage measurement with AUTO triggering on a defined shunt. This function is always used when a load with integrated shunt is connected to a control unit pin and the current is to be measured on the integrated shunt. Currents flowing into the control unit register as positive.<BR>
|
||||
</P>
|
||||
<P CLASS="ParameterTitel">
|
||||
<A NAME="pgfId=8687">
|
||||
</A>
|
||||
Testing Points</P>
|
||||
<P CLASS="ParameterBeschreibung">
|
||||
<A NAME="pgfId=8689">
|
||||
</A>
|
||||
The control unit pin to which the load with the integrated shunt is connected is specified as the test point and the reference point.</P>
|
||||
<P CLASS="FktBeschrText">
|
||||
<A NAME="pgfId=8691">
|
||||
</A>
|
||||
</P>
|
||||
<P CLASS="ParameterTitel">
|
||||
<A NAME="pgfId=8693">
|
||||
</A>
|
||||
Parameters</P>
|
||||
<P CLASS="Meßparameter">
|
||||
<A NAME="pgfId=8695">
|
||||
</A>
|
||||
MaxSignalAmplitude</P>
|
||||
<P CLASS="ParameterBeschreibung">
|
||||
<A NAME="pgfId=8697">
|
||||
</A>
|
||||
Largest amplitude occurring on the signal. Can be used to establish the measurement range or to select a suppressor circuit.</P>
|
||||
<P CLASS="Parameter">
|
||||
<A NAME="pgfId=8699">
|
||||
</A>
|
||||
</P>
|
||||
<P CLASS="Meßparameter">
|
||||
<A NAME="pgfId=8701">
|
||||
</A>
|
||||
IntegrationPeriod</P>
|
||||
<P CLASS="ParameterBeschreibung">
|
||||
<A NAME="pgfId=8703">
|
||||
</A>
|
||||
Period over which the signal is integrated.<BR>
|
||||
In the event of superimposed interference signals, it is advisable to select a multiple of the interference signal period as the integration period.<BR>
|
||||
<BR>
|
||||
Standard value: period duration of supply voltage.</P>
|
||||
<P CLASS="Parameter">
|
||||
<A NAME="pgfId=8705">
|
||||
</A>
|
||||
</P>
|
||||
<P CLASS="Meßparameter">
|
||||
<A NAME="pgfId=8707">
|
||||
</A>
|
||||
Shuntresistor</P>
|
||||
<P CLASS="ParameterBeschreibung">
|
||||
<A NAME="pgfId=8709">
|
||||
</A>
|
||||
For selection of resistor value see MSL Catalogue, Implementation of Modules (Simulated Loads).</P>
|
||||
<P CLASS="Parameter">
|
||||
<A NAME="pgfId=8711">
|
||||
</A>
|
||||
</P>
|
||||
<P CLASS="Beispiel">
|
||||
<A NAME="pgfId=8715">
|
||||
</A>
|
||||
Example<BR>
|
||||
</P>
|
||||
<DIV>
|
||||
<H6 CLASS="Body">
|
||||
<A NAME="pgfId=8718">
|
||||
</A>
|
||||
</H6>
|
||||
<TABLE BORDER="1">
|
||||
<TR>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=667">
|
||||
</A>
|
||||
DCI</P>
|
||||
</TD>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=669">
|
||||
</A>
|
||||
1,0.02,0.1</P>
|
||||
</TD>
|
||||
</TR>
|
||||
</TABLE>
|
||||
<P CLASS="Normal">
|
||||
<A NAME="pgfId=8721">
|
||||
</A>
|
||||
<BR>
|
||||
Test circuit:<BR>
|
||||
<BR>
|
||||
<IMG SRC="funktionen-4.gif" ALIGN="BASELINE">
|
||||
<BR>
|
||||
</P>
|
||||
<P CLASS="Normal">
|
||||
<A NAME="pgfId=8724">
|
||||
</A>
|
||||
<BR>
|
||||
Diagram:<BR>
|
||||
<BR>
|
||||
<IMG SRC="funktionen-5.gif" ALIGN="BASELINE">
|
||||
<BR>
|
||||
</P>
|
||||
</DIV>
|
||||
<DIV>
|
||||
<H6 CLASS="Body">
|
||||
<A NAME="pgfId=8727">
|
||||
</A>
|
||||
</H6>
|
||||
<TABLE BORDER="1">
|
||||
<TR>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=676">
|
||||
</A>
|
||||
tID</P>
|
||||
</TD>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=678">
|
||||
</A>
|
||||
IntegrationPeriod</P>
|
||||
</TD>
|
||||
</TR>
|
||||
<TR>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=684">
|
||||
</A>
|
||||
tPS</P>
|
||||
</TD>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=686">
|
||||
</A>
|
||||
Period of the interference signal</P>
|
||||
</TD>
|
||||
</TR>
|
||||
<TR>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=692">
|
||||
</A>
|
||||
tN</P>
|
||||
</TD>
|
||||
<TD ROWSPAN="1" COLSPAN="1">
|
||||
<P CLASS="Tabelle">
|
||||
<A NAME="pgfId=694">
|
||||
</A>
|
||||
Period of mains power supply</P>
|
||||
</TD>
|
||||
</TR>
|
||||
</TABLE>
|
||||
<P CLASS="Normal">
|
||||
<A NAME="pgfId=8729">
|
||||
</A>
|
||||
</P>
|
||||
<P CLASS="Normal">
|
||||
<A NAME="pgfId=8731">
|
||||
</A>
|
||||
Figure 2: Indirect current measurement on a shunt</P>
|
||||
<P CLASS="Normal">
|
||||
<A NAME="pgfId=8733">
|
||||
</A>
|
||||
</P>
|
||||
</DIV>
|
||||
</DIV>
|
||||
</BODY>
|
||||
</HTML>
|
||||